Universities, research institutes and educational organizations have now better access to the superior PowerFactory technology. As we observe an increased demand in modeling of modern power systems such as distributed generation and wind energy, DIgSILENT has decided to make two special versions of the Enterprise Package available: PF4E and PF4R. Both packages allow full access to those functions which are required to model and analyze most complex power systems such as power electronic devices, unbalanced operation or AC/DC systems. All functions are included which are required to simulate steady state operation incl. harmonic load flow, protection, reliability and time domain simulations ranging from microseconds to hours (from EMT to long term stability).
PowerFactory4Education (PF4E)
PowerFactory4Research (PF4R)
Both packages are based on the Enterprise functionality covering the following PowerFactory functions:
DIgSILENT Base Functions
Load Flow Analysis
Fault Analysis
DIgSILENT Stability Functions:
DIgSILENT Harmonic Analysis:
DIgSILENT Protection Functions:
DIgSILENT Reliability Analysis
DIgSILENT Distribution Functions
DIgSILENT PSS/E Compatibility
PowerFactory4Education (PF4E)
- Included functions: PowerFactory Enterprise
- Maximum bus limitation: 50
- Number of users: 25
- Type of license server: Network
- Support: free installation support; limited user support
- Type of license: For educational purposes only (e.g. seminars, student projects, thesis, exercises, etc.)
PowerFactory4Research (PF4R)
- Included functions: PowerFactory Enterprise
- Maximum bus limitation: unlimited
- Number of users: 1
- Type of license server: Network
- Support: free installation support; full user support
- Type of license: For research purposes only (e.g. projects financed by governments and other non-profit organizations)
Both packages are based on the Enterprise functionality covering the following PowerFactory functions:
DIgSILENT Base Functions
- Hierarchical, object-oriented database and Object Browser
- Single-user database server for 1 simultaneous user
- Integrated Network Expansion Stage & Study Case Administration
- Multiple-Window & Multiple-Graphic Single Line
- DPL Script Language
- DOLE interface for SCADA and GIS
- Network Reduction
- Voltage stability
- Contingency Analysis
Load Flow Analysis
- Load Flow for 1-Phase AC/DC and 2-,3- Phase AC Systems
- Balanced and Unbalanced Load Flow
- Station Control, Network Control and Transformer Tap-Changer Control
Fault Analysis
- VDE, IEC, ANSI and Complete Method
- General Fault Analysis for 1-Phase AC/DC and 2-,3- Phase AC Systems
DIgSILENT Stability Functions:
- Balanced / unbalanced AC/DC systems
- RMS and EMT modeling, long-term stability
- Frames and Flexible DL++ modeling
- Eigenvalue analysis
DIgSILENT Harmonic Analysis:
- Balanced / unbalanced harmonics load flow
- Frequency Sweep
DIgSILENT Protection Functions:
- Distance relay modeling
- Time-overcurrent relay modeling
- Device response checks
DIgSILENT Reliability Analysis
DIgSILENT Distribution Functions
DIgSILENT PSS/E Compatibility