Announcement
Collapse
No announcement yet.
DIgSILENT GridCode Software
Collapse
X
Collapse
-
DIgSILENT GridCode Software
New rules and grid codes to connect generators to the grid are emerging worldwide. In every country or region, the operators responsible for the safety and reliability of the power system have established different requirements to connect renewable generation systems to transmission and distribution networks. Such requirements are highly dependent upon the characteristics of individual power systems.
DIgSILENT has developed and released a new test verification tool called DIgSILENT GridCode v1.0, in response to the need to verify whether a wind farm, solar plant, or any other generator is compliant with local Grid Code requirements on basis of unit tests executed. Some of the functions can be verified off-line or on-line. DIgSILENT GridCode is already being used by manufacturers and laboratories during field testing of wind turbines to verify compliance.
Among many others, DIgSILENT GridCode compliance verfication functions are: Verification of generator response during voltage dips and supervision of power plant non-disconnection, according to the selected grid code or other international standards (Spain-REE, Germany-E.ON and MV, England. NGC, France-RTE, IEC-61400-21 Ed.2,others). Other requirements from classical power quality assessment, such as the flicker level according to IEC-61000-4-15 or harmonic emission levels according to IEC-61000-4-7 up to most modern methods in power quality assessment for renewables incl. IEC-61400-21. The application can be automated and integrated into existing SCADA systems, but can also run on a workstation as an off-line verification tool.
DIgSILENT GridCode v1.0 key features include; Data Visualizer to plot data series and graphs, GridCode Compliance to check the compliance with given requirements. The following Grid Codes are supported, Model Validation to check if simulation results (e.g. generated by PowerFactory) and test result are matching, File Editor to post-process data files and speed up the analysis, Flickermeter IEC 61000-4-15 to assess flicker emission levels, Harmonics IEC 61000-4-7 to assess harmonics levels, Toolbox IEC 61400-21 Measurement and assessment of power quality characteristics of grid connected wind turbines. to calculate instantaneous flicker, flicker coefficients, flicker during switching operations, to assess current harmonic emissions, inter-harmonics and higher frequency component emission levels, observation of the evolution in time of DFT components, and Phasors Viewer to visualize the evolution in time of spatial phasors (fundamental and sequence components, line and phase measurements).
The Demo Version of DIgSILENT GridCode is a limited commercial version available for evaluation during a period of 30 days.
To request a demo version of DIgSILENT GridCode please click here and fill in the form.
For more information, kindly download the attachments.Tags: None
Posting comments is disabled.
Products and Services
Collapse
Latest Forum Posts
Collapse
There are no results that meet this criteria.
What's Going On
Collapse
There are currently 123 users online. 0 members and 123 guests.
Most users ever online was 37,346 at 08:33 PM on 21-02-2020.
Website Statistics
Collapse
Topics: 188
Posts: 326
Members: 10
Active Members: 0
Welcome to our newest member, Peter.
GridCode 2 is released with new features.
More details are here http://www.digsilent.me/dme/showthread.php?382